Fire-Rated Non-Occupancy Building RFP (Rack Fire Protect)

Safe and legally compliant storage of flammable and corrosive chemicals

Storing flammable liquids requires strict safety measures to prevent a serious environmental and fire damage. Flammable liquids can give off enough vapour to form burnable mixtures with air. Explosion protection measures must therefore also be considered. Designed to minimize the risk taking hold in your workplace, the RFP (Rack Fire Protect) is now available in a varied collection of small, medium and large fire rated storages for drums and IBC. The single or double tiered designs will keep dangerous chemicals well organized and correctly separated.

RFP – The first choice for safe chemical storage:

  • Suitable for the storage, dispensing or removal of flammable and water-polluting substances
  • Capacity for up to 12 IBC / 48 Drums
  • Up to 2-hours of fire protection both inside and out
  • No thermal gaps: Due to the continuous insulation inexpensive heating or air conditioning is possible
  • Long-lasting corrosion protection


Compliant with US standards

  • Execution according to FM Approval 6049
  • Complies with the regulations of NFPA (fire protection), OSHA (occupational safety), and EPA (environmental protection, specifically EPA-CFR 40)
  • The electrical components are UL-certified
  • Roll-Up doors with certificate (NFPA / UL listing) corresponding to the International Building Code (IBC)
Compliant with US standards

Proven standard worldwide

DENIOS has over 35 years of engineering experience and is represented in over 20 countries in America, Europe and Asia. The Chemical storage RFP is designed in Germany and manufactured in the USA.

 

 


Extensively tested for quality and safety

  • Complete system 2-hours-fire-tested at 2192 °F (1000 °C) in Germany and France
  • Use of only tested and approved components
  • Statics proven under load tests
  • Highest precision through modern production technology
  • Strict quality checks on every order

Stable and durable construction

  • Fireproof, 150 mm mineral wool panels (A class material, non-combustible) with high insulation properties
  • Double frame construction for 2 hours fire protection from inside and outside: No significant temperature increase on the outside in the event of a fire inside
  • Load-bearing structures made of hot-dip galvanized steel
  • Long-lasting corrosion protection with the use of fully-galvanized base material and high-quality Durathane paint
  • Welded/Painted/Tested, one-piece sump meets FM Approval (25% capacity rule)
  • Equiped with fire-rated roll-up doors with UL-Listing
  • Built-in shelves
  • Roof drainage against water damage
  • Meets the local structural requirements (wind, earthquake, snow loads)
  • Safety lock to protect against unauthorized access
  • Installation inside, next to or near buildings

RFP models for needs-based storage

Description Storage Capacity Sump Volume External Dimensions* Bay Dimensions Tier Dimensions
(Upper / Lower)
# of Tiers Load Capacity
per Tier
RFP 115.20 1 IBC / 4 Drums 350 gallons 101" x 73" x 112" 75" x 54" x 80" 1 Tier 5,000 lbs
RFP 315.20 2 IBC / 8 Drums 350 gallons 151" x 73" x 112" 120" x 54" x 80" 1 Tier 10,000 lbs
RFP 315.30* 4 IBC / 16 Drums 350 gallons 151" x 73" x 153" 120" x 54" x 121"

102" x 50" x 57"
102" x 54" x 46"

2 Tier 20,000 lbs
RFP 615.20 4 IBC / 16 Drums 350 gallons 282" x 73" x 112" 120" x 54" x 80" 1 Tier 20,000 lbs
RFP 615.30* 8 IBC / 32 Drums 700 gallons 282" x 73" x 153"

120" x 54" x 121"

102" x 50" x 57"
102" x 54" x 46"
2 Tier 40,000 lbs
RFP 815.30* 12 IBC / 48 Drums 1,050 gallons 389" x 73" x 153" 170" x 54" x 121" 152" x 50" x 57"
154" x 54" x 46"
2 Tier 60,000 lbs


*These models have adjustable racking.


Customized solutions through various equipment

The equipment plays a decisive role in the individual product configuration. Let our experienced experts coordinate your requirements with you and develop a tailor-made one solution.

Heating, ventilation, air conditioning and cooling technology for regulation of the indoor climate. Reliable air conditioning for heat or frost-sensitive stored goods is necessary in many industrial areas in order to protect stored chemicals from harmful temperature influences.

Air conditioning

Air conditioning

Optionally available in Ex version (only for indoor use).

Heating

Heating

Available as Ex and nEx versions.

Technical ventilation

Technical ventilation

For effective cross ventilation of the hazmat storage.

 

The control technology is optimally matched to DENIOS chemical buildings. It triggers an optical and acoustic alarm in case of a deviation in measured data. In addition, automatic locking or extinguishing systems are activated, for example. All information is on the operating and display elements clearly presented.

Comfort control

Comfort control

Modern touch panels / displays for indoor or outdoor use with high ease of use.

Basic control

Basic control

Switching logics optimally matched to the storage and process technology from DENIOS.

Enclosure of the control

Enclosure of the control

Enclosure of the control and operating elements to protect against unauthorized operation.

 

Our fire protection equipment is in compliance with the strictest fire protection regulations in order to protect people and the environment. Your task is to find out about the various requirements at an early stage and define measures that reduce the risk of fire prevent as much as possible.

Fire-resistant partitions

Fire-resistant partitions

Fire-resistant partitions for the penetration of the Fire protection storage walls.

Extinguishing technology with aerosol

Extinguishing technology with aerosol

Extinguishing technology with aerosol, without the addition of water.

Fire detectors

Fire detectors

DENIOS fire detectors are equipped with approved multi-sensors, that detect smoke and fire quickly and reliably.

 

If explosion protection is needed according to your assessment, we offer you built-in components that can represent a source of sparks in an appropriate Ex version. Earthing devices (e.g. earthing rail) are optionally available for equipotential bonding.

Air conditioning

Earthing rail

For earthing connection inside the store. Provides the necessary equipotential bonding with an external earthing pin as a connection.

Heating

Earthing set

Earthing bracket for equipotential bonding. Sticker set with warnings.

Technical ventilation

Gas warning equipment

Explosion-proof transmitter for the detection of combustible gases and vapours. Used for preventive fire and explosion protection.

Accessories images shown are for illustration purpose. Actual accessory may vary due to available options in North America.