Spill Barriers Spill Barriers Concrete Berm Manual Spill Barriers Automatic Doorway Spill Barrier Automatic Doorway Flood Barriers Anhamm Automatic Doorway Spill Barriers- FM Approved Chemical Storage Buildings / FM Approved Chemical Storage Buildings / FM Approved Non-Combustible Storage Buildings 2-hour Fire Rated Storage Buildings 4-hour Fire Rated Storage Buildings Chemical Storage Lockers / FM Approved Chemical Storage Lockers / FM Approved FM Approved Hazmat Storage Lockers Non-Combustible 90 mph Construction FM Approved Hazmat Storage Lockers Non-Combustible 150 mph Construction FM Approved Hazmat Storage Lockers Fire Rated 90 mph Construction FM Approved Hazmat Storage Lockers Fire Rated 150 mph Construction Non-Combustible Hazmat Lockers Fire Rated Hazmat Locker IBC Storage Lockers Drum Heating Cabinet Non-Occupancy Hazmat Storage Buildings Non-Occupancy Hazmat Storage Buildings FM Approved Non-Combustible Non-Occupancy Hazmat Storage Buildings FM Approved 2-hour Fire Rated Non-Occupancy Hazmat Storage Buildings FM Approved 4-hour Fire Rated Non-Occupancy Storage Buildings Non-Combustible Non-Occupancy Storage Buildings 2-hour Fire Rated Non-Occupancy Storage Buildings 4-hour Fire Rated Non-Occupancy Storage Buildings Basic Non Combustible Buildings Basic Non Combustible Buildings
Chemical Storage for Drums & Totes
Drum and Tote Handling & Accessories
Flammable Cabinets & Small Volume Storage
Work Safety Equipment
Cleaning & Disposal Equipment
DENIOS
dummy image Contact Contact Denios Request Catalog dummy image Service Workplace Safety Products Video Gallery PDF Catalogs Building & Cabinet Options DENIOS About DENIOS International Safety News Careers & Jobs Product Safety Videos Press Releases
Untitled Document

Anhamm Automatic Doorway Spill Barriers provide the protection to contain those large spills

 

Automatic Doorway Spill Barriers

Recent partnership between Anhamm GmbH and DENIOS-US allows DENIOS to provide Anhamm’s FM Approved Flammable Liquid Barrier to customers in North and Central America!

Tested and approved for retaining/containing flammable chemicals (FM Approved ????)

The Anhamm Automatic Doorway Spill Barriers provide the protection to contain those large spills by closing off any doorway or opening in the affected room at the first sign of flowing liquids.

Federal Regulations along with Local Jurisdictions require that sprinkler water in combination with regulated or hazardous materials be prevented from being released into the environment via sewers, streams, or ground contamination. When a release occurs, fines and clean-up costs can be staggering.

NFPA-30 9.13.3

Curbs, scuppers, special drains, or other suitable means shall be provided to prevent the flow of liquids under emergency conditions into adjacent building areas.

IFC-2704.2.2.3 (2009)

Secondary containment for indoor storage areas shall be designed to contain a spill from the largest vessel plus the design flow volume of fire-protection water calculated to discharge from the fire-extinguishing system over the minimum required system design area or area of the room… for a period of 20 minutes.

OSHA 1910.106 (e) (3) (iv) (a)

Emergency drainage systems shall be provided to direct flammable or combustible liquid leakage and fire protection water to a safe location.  This may require curbs, scuppers, or special drainage systems to control the spread of fire.

OSHA 1910.106 (d) (4) (i)

Openings to other rooms or buildings shall be provided with non-combustible liquid-tight raised sills or ramps at least 4” in height.

 